      NAVOD K PROGRAMUM NA MERENI TEPLOTY S CIDLEM SMT160
             
  cisla portu com:
  com1:HEX $3F8;DEC 1016;com2:HEX $2F8;DEC 760;
  com3:HEX $3E8;DEC 1000;com4:HEX $2E8;DEC 744;
  
  PROGRAM S NAZVEM ODECET.EXE VYTVORI SOUBOR S NAZVEM CAS.HOD,
  SEM SE ZADAVA HODNOTA PO KTERE BUDE AUTOMATICKY ULOZEN DALSI
  ZAZNAM TEPLOTY.POKUD MAME JIZ VYTVORENY SOUBOR CAS.HOD MUZEME
  MENIT HODNOTU POMOCI MANAZERU.V PRIPADE ZE CHCEME POUZE MERIT
  TEPLOTU A NEZAPISOVAT DO SOUBORU ZADAME DO SOUBORU CAS.HOD
  0 "NULU" A PROGRAM BUDE POUZE MERIT TEPLOTU.
  
  PROGRAM S NAZVEM PORT.EXE VYTVORI SOUBOR S NAZVEM COM.POC SEM SE 
  ZADAVA HODNOTA PORTU KDE JE PRIPOJEN PREVODNIK HODNOTU ZADAVAME
  V HEXA TAK JAK JE UVEDENO VYSE,TZV. POKUD JE PREVODNIK PRIPOJEN
  NA COM1 ZADAME TAKTO NUTNO DODRZET : $3F8 A POD.PROGRAM TUTO HODNOTU
  ULOZI DO SOUBORU V DESITKOVE SOUSTAVE TJ.1016.POKUD MAME JIZ VYTVO-
  RENY SOUBOR COM.POC MUZEME HODNOTU MENIT PRIMO V MANAZERU V TOMTO
  PRIPADE ZADAVAME HODNOTU PRIMO V DESITKOVE SOUSTAVE.UVEDENE SOUBORY
  MUSI BYT ULOZENY VE STEJNEM ADRESARI JAKO VLASTNI PROGRAM PRO MERENI
  TEPLOTY AUTOSMT.EXE.
  
  PROGRAM S NAZVEM KALIBR.EXE VYTVORI SOUBOR S NAZVEM IMPULS.MIN SEM
  SE ZADAVA HODNOTA CISLA ZJISTENA PRI KALIBRACI PROGRAMEM KALIBRUJ.
  !!!! VSECHNY VYTVORENE SOUBORY TJ.:CAS.HOD,COM.POC,IMPULS.MIN :,MUSI
  BYT ULEZENY VE STEJNEM ADRESARI JAKO VLASTNI PROGRAM NA MERENI TEPLOTY
  AUTOSMT.EXE.PROGRAM Z TECHTO SOUBORU NACITA HODNOTY!!!.POKUD JE 
  PROGRAM AUTOSMT SPOUSTEN Z DISKETY TATO NESMI BYT CHRANENA PROTI
  ZAPISU.
  
  PROGRAM AUTOSMT.EXE SI SAM VYTVORI SOUBOR S NAZVEM NAMERENO.TXT 
  SEM PAK UKLADA NAMERENE HODNOTY,POKUD JE PROGRAM AUTOSMT.EXE UKO-
  NCEN A PAK ZNOVU SPUSTEN JE DALSI ZAPIS PROVEDEN ZA POSLEDNI NA-
  MERENOU HODNOTU A POKRACUJE DALE,KAZDE NOVE SPUSTENI PROGRAMU 
  AUTOSMT.EXE JE V SOUBORU ODDELENO DATUMEM A HODINOU SPUSTENI.
  
  PROGRAM SMT JE URCEN TAKE K MERENI TEPLOTY PO SPUSTENI SE NAVOLI
  PORT KDE JE PRIPOJEN PREVODNIK,PO VOLBE PORTU SE NAVOLI ZDA BUDEME
  POUZE MERIT TEPLOTU NEBO BUDEME TEPLOTU UKLADAT DO SOUBORU TOTO
  VOLIME PRI SPUSTENI POKUD CHCEME MERIT A UKLADAT DO SOUBORU STIS-
  KNEME KLAVESU A ,POKUD CHCEME POUZE MERIT STISKNEME KLAVESU N,PO
  VOLBE UKLADAT DO SOUBORU ZADAME JMENO SOUBORU A PO JAKE DOBE SE 
  BUDOU NAMERENE HODNOTY UKLADAT.!!! POZOR PROGRAM SMT.EXE TAKE VY-
  UZIVA SOUBOR S NAZVEM IMPULS.MIN PROTO MUSI BYT TENTO SOUBOR VE
  STEJNEM ADRESARI JAKO VLASTNI SOUBOR SMT.EXE.!!!

  NAVOD K PROGRAMU KALIBRUJ.EXE PO SPUSTENI PROGRAMU NAVOLIME PORT
  KDE JE PRIPOJENO CIDLO KTERE CHCEME KALIBROVAT K POCITACI SE KTE-
  RYM BUDE PROVOZOVANO,PO NAVOLENI PORTU SE ZOBRAZI ZADEJ HODNOTU
  bb= SEM ZADAME NAPOPRVE HODNOTU 65000 A STISKNEME KLAVESU ENTER,
  PAK SE JIZ BUDE ZOBRAZOVAT MERENA TEPLOTA PO CTYRECH VTERINACH.
  TUTO HODNOTU POROVNAVAME PODLE KALIBRACNIHO TEPLOMERU(LABORATORNI, 
  LEKARSKY A POD.),POKUD SE TEPLOTY NESHODUJI STISKNEME KLAVESU MEZERNIK
  A ZADAME NOVOU HODNOTU ZA bb,A OPAKUJEME MERENI,PO ZJISTENI SPRAVNE 
  HODNOTY TUTO SI POZNAMENAME NA PAPIR PROGRAM UKONCIME STISKEM KLAVESY 
  ESC.SPUSTIME PROGRAM KALIBR.EXE A SEM ZAPISEME ZJISTENOU HDNOTU A STI-
  SKNEME KLAVESU ENTER.
  KALIBRACI PROVADIME TAK ZE OBA TEPLOMERY TJ.CIDLO SMT SPOLECNE S KALI-
  BRACNIM MAME V NADOBE S VODOU (HRNKU),VODA MUSI BYT POKUD MOZNO ODSTATA.
  ////////////////////////////////////////////////////////////////////////
  Postup po vyrobe prevodniku:
  1) Jako prvni spustime program  KALIBRUJ.EXE a postupujeme jak uvedeno.
  2) Jako druhy spustime program  KALIBR.EXE a postupujeme jak uvedeno.
  3) Jako treti spustime program  ODECET.EXE jsem jako prvni zadame ho-
     notu 0.Tim nam bude program AUTOSMT.EXE pouze merit teplotu.Pokud po
     odzkouseni budeme chtit merit teplotu po 5 minutach zadame hodnotu :
     300,1 munuta= 60 vterin,5minut je 5 x 60=300,jinak muzeme zadavat i 
     zapisovani po hodinach,napr.chceme zapisovat po dvou hodinach 7200.
     Minmalni a Maximalni hodnota mezi odecty muze byt od deseti vterin 
     po hodnotu 2 x za mesic.
  4) Jako dalsi spustime program PORT.EXE a postupujeme jak uvedeno vyse.
  5) Jako dalsi spustime program bud AUTOSMT.EXE nebo SMT.EXE to je jiz
     na uzivateli.!! POZOR !!
     VYTVORENE POMOCNE PROGRAMY CAS.HOD,COM.POC,IMPULS.MIN SE MUSEJI 
     NACHAZET VE STEJNEM ADRESARI JAKO VLASTNI PROGRAMY NA MERENI TEPLOTY
     TJ.AUTOSMT.EXE A SMT.EXE.!!! POKUD JSOU PROGRAMY AUTOSMT.EXE,SMT.EXE
     SPOUSTENY Z DISKETY TAK TATO !!! NESMI BYT BLOKOVANA PROTI !! ZAPISU.

     